Get Essential, free

Ponturin and Arc stream sediments at Peisey-Nancroix

Savoie, Ponturin valley (Tarentaise), France

Sediments

Type
Sediment

Former Pb-Ag mining and metallurgical site of Peisey-Nancroix (1734-1866), abandoned for over 150 years: on-site roasting and smelting from 1745 to 1824. Metallurgical wastes have a homogeneous δ123Sb (+0.72 ± 0.07 ‰), clearly heavier than the ore (-0.28 to +0.10 ‰), whereas Pb does not distinguish them; contaminated soils (about +0.46 ‰) owe 44 to 78 % of their Sb to slags according to a binary mixing (Guillevic et al., 2024). Ponturin sediments upstream (SED-12, reference) and downstream of the site, weakly enriched (Pb EF below 3, Sb below 2). Indicative coordinates (village).

δ123Sb in ‰ (per mil) Values of the same system

Standard : SPEX CertiPrep, lot 24-175SBX

ValueRangenMineral or matrixSource
0.23 ± 0.04 ‰1stream sediment SED-12
Single analysis; ± 0.04 (2 SD); sample SED-12; 12 mg/kg Pb, 2 mg/kg Sb; upstream, uncontaminated reference.
Guillevic et al. (2024), Multi-isotope (Pb, Sb) approach to trace metallic contaminant so…
0.18 ± 0.03 ‰1stream sediment SED-03
Single analysis; ± 0.03 (2 SD); sample SED-03; 22 mg/kg Pb, 3 mg/kg Sb.
Guillevic et al. (2024), Multi-isotope (Pb, Sb) approach to trace metallic contaminant so…
0.25 ± 0.06 ‰1stream sediment SED-13*
Single analysis; ± 0.06 (2 SD); sample SED-13*; 15 mg/kg Pb, 1 mg/kg Sb.
Guillevic et al. (2024), Multi-isotope (Pb, Sb) approach to trace metallic contaminant so…

206Pb/207Pb isotope ratio, no unit Values of the same system

Standard : NIST SRM 981

ValueRangenMineral or matrixSource
1.208 ± 0.0041stream sediment SED-12
Single analysis; ± 0.004; sample SED-12; 12 mg/kg Pb, 2 mg/kg Sb.
Guillevic et al. (2024), Multi-isotope (Pb, Sb) approach to trace metallic contaminant so…
1.189 ± 0.0041stream sediment SED-03
Single analysis; ± 0.004; sample SED-03; 22 mg/kg Pb, 3 mg/kg Sb.
Guillevic et al. (2024), Multi-isotope (Pb, Sb) approach to trace metallic contaminant so…
1.1871stream sediment SED-13*
Single analysis; ± below 0.001 (MC-ICP-MS); sample SED-13*; 15 mg/kg Pb, 1 mg/kg Sb.
Guillevic et al. (2024), Multi-isotope (Pb, Sb) approach to trace metallic contaminant so…

208Pb/206Pb isotope ratio, no unit Values of the same system

Standard : NIST SRM 981

ValueRangenMineral or matrixSource
2.051 ± 0.0051stream sediment SED-12
Single analysis; ± 0.005; sample SED-12; 12 mg/kg Pb, 2 mg/kg Sb.
Guillevic et al. (2024), Multi-isotope (Pb, Sb) approach to trace metallic contaminant so…
2.068 ± 0.0051stream sediment SED-03
Single analysis; ± 0.005; sample SED-03; 22 mg/kg Pb, 3 mg/kg Sb.
Guillevic et al. (2024), Multi-isotope (Pb, Sb) approach to trace metallic contaminant so…
2.0761stream sediment SED-13*
Single analysis; ± below 0.001 (MC-ICP-MS); sample SED-13*; 15 mg/kg Pb, 1 mg/kg Sb.
Guillevic et al. (2024), Multi-isotope (Pb, Sb) approach to trace metallic contaminant so…

Deposits of the same type

Cite this page

IsoFind Atlas (2026). Ponturin and Arc stream sediments at Peisey-Nancroix, isotope signatures. https://www.isofind.tech/isotopes/en/sites/sediments-du-ponturin-et-de-l-arc-a-peisey-nancroix/ (accessed 2026-10-16).

@misc{isofind2026ponturinandarcstreamsediments,
  title = {Ponturin and Arc stream sediments at Peisey-Nancroix, isotope signatures},
  author = {{IsoFind Atlas}},
  year = {2026},
  url = {https://www.isofind.tech/isotopes/en/sites/sediments-du-ponturin-et-de-l-arc-a-peisey-nancroix/},
  note = {Accessed 2026-10-16}
}

Updated : 2026-10-16